BACKGROUND
Radiohybrid (rh) F-rhPSMA-7.3 is a novel high-affinity prostate-specific membrane antigen (PSMA)-targeting radiopharmaceutical for prostate cancer (PCa) imaging.
OBJECTIVE
To evaluate the diagnostic performance and safety of F-rhPSMA-7.3 in newly diagnosed PCa patients planned for prostatectomy.
DESIGN, SETTING, AND PARTICIPANTS
Data on F-rhPSMA-7.3 were reported from the phase 3 prospective, multicentre LIGHTHOUSE study (NCT04186819).
OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS
Patients underwent positron emission tomography/computed tomography (PET/CT) 50-70 min after an injection of 296 MBq F-rhPSMA-7.3. Images were interpreted locally and by three blinded independent readers. The coprimary endpoints were patient-level sensitivity and specificity for the detection of pelvic lymph node (PLN) metastases, validated using histopathology at PLN dissection. Prespecified statistical thresholds (lower bounds of 95% confidence interval [CI]) were set at 22.5% for sensitivity and 82.5% for specificity.
RESULTS AND LIMITATIONS
Of 372 patients screened, 352 had evaluable F-rhPSMA-7.3-PET/CT and 296 (99 [33%] with unfavourable intermediate-risk [UIR] and 197 [67%] with high-/very-high-risk [VHR] PCa) subsequently underwent surgery. As per the independent reads, 23-37 (7.8-13%) patients had F-rhPSMA-7.3-positive PLN. Seventy (24%) patients had one or more positive PLNs on histopathology. The sensitivity for PLN detection was 30% (95% CI, 19.6-42.1%) for reader 1, 27% (95% CI, 17.2-39.1%) for reader 2, and 23% (95% CI, 13.7-34.4%) for reader 3, not meeting the prespecified threshold. Specificity was 93% (95% CI, 88.8-95.9%), 94% (95% CI, 89.8-96.6%), and 97% (95% CI, 93.7-98.7%), respectively, exceeding the threshold for all readers. Specificity was high (≥92%) across both risk stratifications. Sensitivity was higher among high-risk/VHR (24-33%) than among UIR (16-21%) patients. Extrapelvic (M1) lesions were reported for 56-98/352 (16-28%) patients who underwent F-rhPSMA-7.3-PET/CT irrespective of surgery. Verification of these (predominantly by conventional imaging) gave a verified detection rate of 9.9-14% (positive predictive value, 51-63%). No serious adverse events were observed.
CONCLUSIONS
Across all risk stratifications, F-rhPSMA-7.3-PET/CT had high specificity, meeting the specificity endpoint. The sensitivity endpoint was not met, although higher sensitivity was noted among high-risk/VHR than among UIR patients. Overall, F-rhPSMA-7.3-PET/CT was well tolerated, and identified N1 and M1 disease prior to surgery in newly diagnosed PCa patients.
PATIENT SUMMARY
In order to select the most appropriate treatment for patients with prostate cancer, it is critical to diagnose the disease burden accurately at initial diagnosis. In this study, we investigated a new diagnostic imaging agent in a large population of men with primary prostate cancer. We found it to have an excellent safety profile and to provide clinically useful information regarding the presence of disease beyond the prostate.