Image-based multichannel vaginal cylinder brachytherapy for vaginal cancer.   
ABSTRACT
PURPOSE
To investigate the clinical feasibility and treatment outcomes of image-based high-dose-rate (HDR) brachytherapy using an intracavitary multichannel vaginal cylinder for the definitive treatment of vaginal cancers.
METHODS AND MATERIALS
A total of 41 patients with vaginal cancer (24% primary vaginal and 76% recurrence from other gynecologic primaries) treated with definitive radiotherapy ± chemotherapy including image-based HDR brachytherapy with a multichannel vaginal cylinder were included in the study. Image-based brachytherapy was completed using either CT- (41%) or MR-based planning (59%) with each fraction. The high-risk clinical target volume was defined based on the pre- and postexternal beam radiotherapy gross tumor volume. Doses were converted to equivalent dose of 2Gy per fraction. Endpoints examined were dose-volume parameters and early clinical outcomes.
RESULTS
The median high-risk clinical target volume was 24.2 cc (interquartile range [IQR], 12.6), with a median dose to 90% (D90) of 77.1 Gy (IQR, 3.4). The median dose to 2 cc (D(2 cc)) for the bladder, rectum, and sigmoid were 59.4 Gy (IQR, 5.6), 58.2 Gy (IQR, 4.1), and 52.3 Gy (IQR, 5.5), respectively. After a median followup of 16 months (range, 3-35), complete clinical response was documented in 98% of the patients. The 2-year local, regional, and distant control; and disease-free and overall survival were 93%, 100%, 81%, 78%, and 88%, respectively. The 2-year actuarial rate of late Grade 3 or higher toxicity was 4% overall with 0%, 0%, 0%, and 4% for vaginal, bladder, urethral, and gastrointestinal, respectively.
CONCLUSIONS
Image-based HDR brachytherapy using an intracavitary multichannel cylinder seems feasible in definitive vaginal cancer treatment. The described clinical implementation shows promising early clinical outcomes with high rates of local control and little toxicity, which should be validated with extended followup.

Related Questions