Lancet 2021 Aug 27
Implantable loop recorder detection of atrial fibrillation to prevent stroke (The LOOP Study): a randomised controlled trial.
Abstract
Background
It is unknown whether screening for atrial fibrillation and subsequent treatment with anticoagulants if atrial fibrillation is detected can prevent stroke. Continuous electrocardiographic monitoring using an implantable loop recorder (ILR) can facilitate detection of asymptomatic atrial fibrillation episodes. We aimed to investigate whether atrial fibrillation screening and use of anticoagulants can prevent stroke in individuals at high risk.
Methods
We did a randomised controlled trial in four centres in Denmark. We included individuals without atrial fibrillation, aged 70-90 years, with at least one additional stroke risk factor (ie, hypertension, diabetes, previous stroke, or heart failure). Participants were randomly assigned in a 1:3 ratio to ILR monitoring or usual care (control) via an online system in permuted blocks with block sizes of four or eight participants stratified according to centre. In the ILR group, anticoagulation was recommended if atrial fibrillation episodes lasted 6 min or longer. The primary outcome was time to first stroke or systemic arterial embolism. This study is registered with ClinicalTrials.gov, NCT02036450.
Findings
From Jan 31, 2014, to May 17, 2016, 6205 individuals were screened for inclusion, of whom 6004 were included and randomly assigned: 1501 (25·0%) to ILR monitoring and 4503 (75·0%) to usual care. Mean age was 74·7 years (SD 4·1), 2837 (47·3%) were women, and 5444 (90·7%) had hypertension. No participants were lost to follow-up. During a median follow-up of 64·5 months (IQR 59·3-69·8), atrial fibrillation was diagnosed in 1027 participants: 477 (31·8%) of 1501 in the ILR group versus 550 (12·2%) of 4503 in the control group (hazard ratio [HR] 3·17 [95% CI 2·81-3·59]; p<0·0001). Oral anticoagulation was initiated in 1036 participants: 445 (29·7%) in the ILR group versus 591 (13·1%) in the control group (HR 2·72 [95% CI 2·41-3·08]; p<0·0001), and the primary outcome occurred in 318 participants (315 stroke, three systemic arterial embolism): 67 (4·5%) in the ILR group versus 251 (5·6%) in the control group (HR 0·80 [95% CI 0·61-1·05]; p=0·11). Major bleeding occurred in 221 participants: 65 (4·3%) in the ILR group versus 156 (3·5%) in the control group (HR 1·26 [95% CI 0·95-1·69]; p=0·11).
Interpretation
In individuals with stroke risk factors, ILR screening resulted in a three-times increase in atrial fibrillation detection and anticoagulation initiation but no significant reduction in the risk of stroke or systemic arterial embolism. These findings might imply that not all atrial fibrillation is worth screening for, and not all screen-detected atrial fibrillation merits anticoagulation.
Funding
Innovation Fund Denmark, The Research Foundation for the Capital Region of Denmark, The Danish Heart Foundation, Aalborg University Talent Management Program, Arvid Nilssons Fond, Skibsreder Per Henriksen, R og Hustrus Fond, The AFFECT-EU Consortium (EU Horizon 2020), Læge Sophus Carl Emil Friis og hustru Olga Doris Friis' Legat, and Medtronic.
Related Questions
How do you manage asymptomatic non-sustained atrial arrhythmia in patients with single ventricle and Fontan physiology?
This is an excellent, challenging question and I think experts will disagree and debate the issue depending if they are risk-minimizers or cost-minimizers and if patients are worriers (woulda, coulda, shoulda) or data-driven/evidence-based (need to see large studies with proof before action).I like ...
In light of the NOAH-AFNET6 and ARTESiA trials, how would you approach the decision regarding anticoagulation for patients with incidentally-detected AF <24 hrs on pacemakers/defibrillators?
Finding the right answer for subclinical atrial fibrillation is sometimes hard to tease out the subtleties. The 2023 ACC/AHA/HRS atrial fibrillation guidelines were published in Jan 2024 (Joglar et al., PMID 38033089) and a section (6.4.1) is dedicated to patients with CIED without prior atrial fibr...
In what situations/patient population would you consider placing an implantable cardiac monitor in favor of external monitors for long-term dynamic monitoring of atrial fibrillation?
This is an excellent question and I think we need the remainder of the publication to make our best estimates (specifically Table 1 and the n for results, including % ablated - couldn't find online or any pictures of slide data on Twitter). The online MONITOR-AF late-breaking trial abstract is avail...
What percentage of patients with non-sustained focal atrial tachycardia detected on an outpatient Holter develop paroxysmal atrial fibrillation, and how should we identify and treat patients at the highest risk of progressing to PAF?
I agree with most of the points by Dr. @Dr. First Last. I'll go through my train of thought from monitoring to what the %age is (PAT progressing to PAF) to afib management/reasons we care. Apologies for the length of response:1) The right monitoring technology should balance what you are looking for...
Given recent trials for the management of atrial fibrillation with an early ablation strategy (for example, EAST-AFNET 4, EARLY-AF, PROGRESSIVE-AF, STOP-AF), what is your approach to determining the appropriate timing for ablation in patients with atrial fibrillation?
I agree with Dr. @Dr. First Last. I also usually start with an antiarrhythmic drug and then offer ablation if the drug is not tolerated or is ineffectual. This is a shared decision-making process - some patients want nothing to do with drugs and prefer ablation and others want to try multiple drugs ...
For which stroke patients, if any, do you recommend implantable loop recorder for long-term cardiac monitoring and why?
Fantastic and pertinent question! I won't pretend that I have an answer, but do have a few thoughts that may help frame further discussion: We derive our evidence for the efficacy of anticoagulation in stroke prevention from older trials designed to answer that specific question (SPAF, etc.). In the...