Mednet Logo

Do you treat the normal pancreas as an organ at risk when delivering abdominal radiation therapy?

Do you ever contour the normal pancreas, use any dose constraints, and/or counsel patients on any possible late effects such as pancreatic insufficiency?
5 Answers
Mednet Member
Mednet MemberInvited Expert
Radiation Oncology · Memorial Sloan-Kettering Cancer Center
Answered on

This is a great question. We do not do that because we have not seen any convincing evidence of exocrine or endocrine insufficiency caused by radiation at any dose. In fact, from surgical patients, we know that only a small volume of residual pancreas is needed to prevent insulin dependence. The pan...

Join for free or sign in to see the full answer

Mednet Member
Mednet MemberInvited Expert
Radiation Oncology · University of North Carolina at Chapel Hill
Answered on

I also do not put any specific constraints on the pancreas. For most patients, there is plenty of excess function, although I have seen an occasional patient who I think has developed endocrine insufficiency with a combination of surgery, pancreatitis (not related to the RT), and RT. Most of the dis...

Join for free or sign in to see the full answer

Mednet Member
Mednet MemberInvited Expert
Radiation Oncology · UPMC Hillman Cancer Center
Answered on

For pediatric cases, I do contour the pancreas and pay particular attention to the tail dose because of this paper: de Vathaire et al., PMID 22921663.

Join for free or sign in to see the full answer

Mednet Member
Mednet MemberInvited Expert
Radiation Oncology · Mayo Clinic
Answered on · Updated on

I’ve never ordered a hemoglobin A1c on an oncology patient during follow up and I don’t routinely contour the pancreas as an OAR. I suspect I’m joined by most of our field in that regard. That said, it’s intuitive that islet cells would share the radiosensitivity of other endocrine tissues and that ...

Join for free or sign in to see the full answer

Mednet Member
Mednet Member
Radiation Oncology · Mallory Radiotherapy, PLLC
Answered on

SIOPE guidelines recommend the following be contoured as OARs near the spine: larynx, esophagus, thyroid gland, breasts, lungs, heart, liver, stomach, intestine, pancreas, kidneys, and the gonads. However, specific constraints are not given.

So I have included it as an organ at risk on VMAT craniospi...

Join for free or sign in to see the full answer