Is the skin dose adequate when treating a patient prone for breast cancer?

For breast patients being treated in prone position. The plans generally spare the skin more so than in the supine position. If a patient has a superficial tumor bed I would boost with electrons. Do you have minimal limits on what is an acceptable dose to the skin?
1 Answer
Mednet MemberInvited Expert
Radiation Oncology · University of Colorado School of Medicine
Answered on · Updated on

Good Question! This is how you can approach the issue in any patient position:

The skin is not a target in whole breast radiation planning. When contouring breast tissue, typically 5 mm from skin surface is eliminated/deleted when creating this structure. Plan your whole breast treatment after creating a lumpectomy-bed-PTV structure in addition to the whole breast, even if not planning to boost. Then, when evaluating your DVHs of any whole breast plan, you can ensure that coverage to the PTV-lumpectomybed is adequate. For me, it is most important to have PTV_lumpectomybed coverage (whether you use 95/95 or 100/95) than the whole breast. This is your highest risk area. For lateralized lumpectomy beds, it is often necessary to use 6mvx photon...

Join for free or sign in to see the full answer