International journal of radiation oncology, biology, physics 2010-01-01
Long-term toxicity following 3D conformal radiation therapy for prostate cancer from the RTOG 9406 phase I/II dose escalation study.   
ABSTRACT
PURPOSE
To update the incidence of late toxicity of RTOG 9406, a three-dimensional conformal radiation therapy (3DCRT) dose escalation trial for prostate cancer.
METHODS AND MATERIALS
A total of 1,084 men were registered to this Phase I/II trial of 3DCRT (eligible patients, 1,055). The dose for level I was 68.4 Gy; 73.8 Gy for level II; 79.2 Gy for level III; 74 Gy for level IV; and 78 Gy for level V. Patients in levels I to III received 1.8 Gy/fraction, and those in levels IV to V received 2.0 Gy/fraction. Disease group I patients were treated at the prostate only, group 2 patients were treated at the prostate and at the seminal vesicles with a prostate boost, and group 3 patients were treated at the prostate and seminal vesicles. The median follow-up period for surviving patients was 6.1 y (level V) to 12.1 y (level I).
RESULTS
The incidence rates of RTOG grade 3 or less gastrointestinal or genitourinary toxicity were 3%, 4%, 6%, 7%, and 9% in group 1 and 6%, 2%, 6%, 9%, and 12% in group 2 at dose levels of I, II, III, IV, and V, respectively. In group 1, level V patients had a higher probability of grade 2 late or greater gastrointestinal or genitourinary toxicity than those in levels I, II, and III (hazard ratio [HR] = 1.93, p = 0.0101; HR = 2.29, p = 0.0007; HR = 2.52, p = 0.0002, respectively). In group 2, dose level V patients had a higher probability of grade 2 or greater late gastrointestinal or genitourinary toxicity than those in dose levels II, III, and IV (HR = 2.61, p = 0.0002; HR = 2.22, p = 0.0051; HR = 1.60, p = 0.0276, respectively).
CONCLUSIONS
Tolerance to high-dose 3DCRT remains excellent. There is significantly more grade 2 or greater toxicity with a dose of 78 Gy at 2 Gy/fraction than with 68.4 Gy to 79.2 Gy at 1.8 Gy/fraction and with 74 Gy at 2 Gy/fraction.

Related Questions

RTOG 0815 protocol says 1 cm from base of SV in any direction. Some contour the SV visible in the slices within 1 cm sup/inf from base of SV.  P...