Mednet Logo
HomeRadiation OncologyQuestion

What dose constraints do you use for OARs when treating with breast IMRT?

1 Answers
Mednet Member
Mednet Member
Radiation Oncology · Varian Medical Systems/Allegheny health network

We follow dose constraints from ongoing NRG studies of breast plus RNI with the only difference being, to focus more on dose homogeneity and make sure V 105 for ipsilateral breast is <10%, and mean heart dose of heart and LAD if possible, below 2 Gy.