Mednet Logo
HomeRadiation OncologyQuestion

What small bowel constraint do you use when planning standard/moderately hypofx EBRT for prostate cancer?

4
1 Answers
Mednet Member
Mednet Member
Radiation Oncology · Northside Hospital Atlanta

For conventional fxn (1.8 Gy)

  • Max dose 52 Gy per RTOG Prostate Consensus Group (PMID:18947938)
    • Personally, use 50 Gy
  • V45 <195 cc per QUANTEC
    • Personally, push lower to <135 cc

For moderate hypofxn (2.5 Gy)

  • V40 <1% per Duke constraints (PMID:28244406)

To the best of my knowledge, CHHip (60 Gy/...

Register or Sign In to see full answer