How do you use higher photon energies in your treatment of breast cancer with tangent fields?

4 Answers
Mednet Member
Mednet Member
Radiation Oncology · Varian Medical Systems/Allegheny health network

Mixed energy use is very common in large breast to achieve dose homogeneity. In our dosimetric study, mixed energy use was about 65% with the goal to keep V105 low. The contribution from high energy can vary from 10-50%.

Chen et al., PMID 29548340

Register or Sign In to see full answer

Mednet Member
Mednet Member
Radiation Oncology · Mayo Clinic Hospital

I use 10 MV when needed for breast planning for large breasted patients. Typically 6/10 mix is reasonable, occasionally 10/10 on tangents. When using 6/10, I usually keep 6 on the side closest to the cavity to minimize the risk for under-dosing of the cavity.

Register or Sign In to see full answer

Mednet Member
Mednet Member
Radiation Oncology · Allegheny Health Network, Pittsburgh

In larger breasted patients, I routinely use higher energies. We typically start with a 6 MV plan and see what the hot spots are like and then add in 10 or 15. While uncommon, in very large breasted patients, we may go completely with high energy tangents. In such cases, we may look at adding a smal...

Register or Sign In to see full answer

Mednet Member
Mednet Member
Radiation Oncology · Northeast Alabama Regional Medical Center

High energy photon beams in breast, and lack of surface dose, is a more complex issue than in other body sites. And it's more complex on the side of: the surface dose is higher than one might expect from looking at a photon depth dose curve from a beam aimed perpendicular to the measurement medium. ...

Register or Sign In to see full answer