Mednet Logo
HomePulmonologyQuestion

How do you use IVC caliber and collapsibility to guide decisions about diuresis?

1
4 Answers
Mednet Member
Mednet Member
Hospital Medicine · Oregon Health and Science University

I use IVC caliber in conjunction with my lung exam to assist with the assessment of right and left atrial pressures respectively. The IVC assessment has many caveats in different patient populations, and evaluation with POCUS can be done in two planes to better understand IVC shape.

Caveats - IVC siz...

Register or Sign In to see full answer

Mednet Member
Mednet Member
Cardiology · Heart And Vascular Center Of Arizona

It is pretty reliable to estimate RA pressure in the non-intubated patient.

In the absence of pHTN, this can be used in conjunction with labs to help guide management.

In the ICU patient, they frequently have arterial lines, so I would have the team transduce the central line 1-2 times a day to foll...

Register or Sign In to see full answer

Mednet Member
Mednet Member
Hospital Medicine · Northwestern University

I agree with all the points made by Dr. @Dr. First Last. I rarely use IVC metrics as an isolated marker to guide diuresis (except when measures are at the low end of the extreme - suggesting RAP <5mmHg). Also agree that there are several important technical, mechanical, and physiological pitfalls re...

Register or Sign In to see full answer

Mednet Member
Mednet Member
Pulmonology · Westchester Medical Center

Static CVP measurements (for which IVC measurements are a proxy) are confounded by several factors, including abdominal pressures and mechanical ventilation. Only in the extreme (CVP <5, or IVC diam <2.1 cm with >50% collapse with respiration) is it potentially informative in diuresis decisions. I m...

Register or Sign In to see full answer