What dose-volume constraint should be used for the normal brain parenchyma in a patient receiving 5-fraction SBRT?

I have seen small amounts of evidence for V4<20 cc and V14<7 cc, but overall, it seems like there is little published on this issue.
5 Answers
Mednet Member
Mednet Member
Radiation Oncology · University of Missouri at Columbia, Ellis Fischel Cancer Cener
Answered on

This is tough, because most of the literature is based upon single fraction SRS for 1-3 lesions. There are no one criteria for brain doses for multi-session treatments as stated above. Tumor coverage is most paramount, and I agree with the need to respect the adjacent structure doses and to optimize...

Join for free or sign in to see the full answer

Mednet Member
Mednet MemberInvited Expert
Radiation Oncology · Oakland University William Beaumont School of Medicine
Answered on

We do not have established thresholds for V12-V16 for fractionated SRS and adverse events especially limiting dose evaluation to the "normal" brain.

We all need to remember, that the optimal models for estimating toxicity post-SRS include the target volume. YOUR TARGET IS YOUR TOXICITY. So first clin...

Join for free or sign in to see the full answer

Mednet Member
Mednet Member
Radiation Oncology · Northside Hospital Atlanta
Answered on

Agree with @Dr. First Last. Prioritize target and aim for V12 < 10 cc if possible. If not, don’t sweat as the UK consortium and AAPM TG 101, though older, did not have a 5 fxn SRS constraint for normal brain. Should always try to aim for as low as possible though.

If you want a metric to make you fe...

Join for free or sign in to see the full answer

Mednet Member
Mednet MemberInvited Expert
Radiation Oncology · Columbia University Irving Medical Center
Answered on · Updated on

I don't have a hard dose-volume constraint for normal brain parenchyma. Depending on the case (brain mets vs benign brain tumors) I would prioritize target coverage, selectivity and gradient/conformity index. The more likely I'm able to keep my isodoses tight the less spillage into normal brain pare...

Join for free or sign in to see the full answer

Mednet Member
Mednet Member
Radiation Oncology · CCare
Answered on

After the publication of these two articles, are people using these for V25 and V30 for brain? What if unable to meet constraint?

BrainV25 > 16 cm3 or BrainV30 > 10 cm3

Andruska et al., PMID 33310010.

Faruqi et al., PMID 31928848.

Join for free or sign in to see the full answer